18609172522Laura@ztmetal.com
enLanguage

Medical Titanium Disc for Dental Implant Abutments: Grade 2 or Grade 23?

Apr 11, 2026

Leave a message

When it comes to manufacturing dental implant abutments, material selection is not just a technical decision-it directly affects clinical success, long-term stability, and patient safety. Among the most widely used materials, Grade 2 (ASTM F67) and Grade 23 (ASTM F136 Ti-6Al-4V ELI) titanium discs dominate the global dental market.

But which one is truly better for your dental lab or manufacturing business? This article breaks down the key differences from mechanical strength, corrosion resistance, and cost-effectiveness-helping international buyers and lab owners make informed decisions.

Strength Comparison: Which Grade Survives Long-Term Masticatory Forces?

One of the most critical requirements for implant abutments is the ability to withstand continuous chewing forces (masticatory loads) over many years.

Grade 2 Titanium (ASTM F67)

Grade 2 is a commercially pure titanium widely used in dental applications. It offers:

Moderate strength (~275 MPa yield strength)

Excellent ductility and flexibility

Good performance in low-to-moderate load scenarios

However, because it is unalloyed, its fatigue resistance is limited compared to titanium alloys. This means that under repeated chewing cycles, long-term durability can be a concern-especially for posterior (molar) restorations.

Grade 23 Titanium (ASTM F136, Ti-6Al-4V ELI)

Grade 23 is a high-performance titanium alloy specifically engineered for medical implants:

1.5–2× higher strength than pure titanium

Superior fatigue resistance under cyclic loading

Enhanced fracture toughness for long-term reliability

Its alpha-beta alloy structure (with aluminum and vanadium) significantly improves resistance to microcracks and mechanical failure, making it ideal for high-load areas.

Key Takeaway for Buyers

Choose Grade 23 for implant abutments and load-bearing restorations

Choose Grade 2 for less demanding components or cost-sensitive cases

For dental labs targeting premium implant systems, Grade 23 is increasingly becoming the preferred global standard.

Corrosion Resistance in Oral Environment: What Clinical Data Reveals

The oral cavity is a highly corrosive environment, exposed to saliva, fluctuating pH, bacteria, and temperature changes. Material stability is essential.

Grade 2 Titanium

Forms a stable TiO₂ oxide layer, providing excellent corrosion resistance

No alloying elements → maximum biocompatibility

Widely considered the "gold standard" for osseointegration

Because of its purity, Grade 2 minimizes the risk of ion release, making it especially attractive for patients with sensitivities.

Grade 23 Titanium

Also develops a strong protective oxide layer

Proven long-term clinical safety despite alloying elements

Comparable corrosion resistance to Grade 2 in physiological environments

Although it contains aluminum and vanadium, the ELI (Extra Low Interstitial) specification ensures minimal impurities and excellent biocompatibility.

Clinical Insight

Both materials perform extremely well in the oral environment. The difference is subtle:

Grade 2 → Maximum purity & biological affinity

Grade 23 → Balanced corrosion resistance + superior mechanical performance

For modern implant systems, corrosion is no longer the limiting factor-mechanical durability is.

Cost-Benefit Analysis for Laboratory Owners Making the Switch

For dental labs and distributors, choosing between Grade 2 and Grade 23 is also a business decision.

Cost Considerations

Grade 2 Titanium

Lower raw material cost

Easier machining → reduced tool wear

Suitable for high-volume, cost-sensitive markets

Grade 23 Titanium

Higher material and processing cost

Harder to machine → increased tooling expense

Requires more advanced CNC capability

Value Perspective

Despite higher upfront costs, Grade 23 often delivers better long-term ROI:

Reduced risk of implant failure

Lower remakes and warranty claims

Higher acceptance in premium markets (EU, US, Japan)

Stronger positioning for high-end dental brands

Market Trend

Globally, there is a clear shift toward:

Grade 23 for implant abutments and CAD/CAM discs

Grade 2 for simpler or temporary restorations

As dental technology evolves, buyers increasingly prioritize performance over price.

Which Titanium Grade Should You Choose?

The decision between Grade 2 and Grade 23 titanium discs ultimately depends on your target market and product positioning:

Choose Grade 2 if you need:

Lower cost

Easier machining

High biocompatibility for simple cases

Choose Grade 23 if you need:

High strength and fatigue resistance

Long-term durability under chewing forces

Premium-quality implant solutions For most modern dental implant abutments, Grade 23 (ASTM F136) offers the best balance of strength, safety, and long-term clinical success.Boost Your Dental Business with the Right Material

If you are a dental lab owner, distributor, or implant system manufacturer, selecting the right titanium grade is more than a technical choice-it's a competitive advantage.

why material sourcing matters

whatever grade you choose,source form a supplier who provides:

full ASTM certification(F67 for Grade 2, F136 for Grade 23)

Batch traceability from ingot to finished disc

ISO 13485 medical device quality management

Consistent dimensions and surface quality

At Xi'an Sino Titanium Metals Co.,Ltd. , we supply both Grade 2 and Grade 23 medical titanium discs for dental implant abutments and CAD/CAM restorations. All products come with complete mill test reports and export documentation.

For more information, please contact our sales team at Laura@ztmetal.com.

Send Inquiry